9.1 Troubleshooting
Troubleshooting is only permitted to approved personnel. This section tells about possible
malfunctions and their solutions. If a malfunction is not in the list that follows, contact your supplier.
Malfunction 1
No supply voltage
Observation 1
The two LEDs D1 and D2 are off (blink code 1.2).
Cause 1
Power supply is externally disconnected.
Solution 1
Connect power supply.
Cause 2
No voltage on the control board.
Solution 2
Measure the supply voltage with a multimeter on the connections X1 of the
control board (A2).
Malfunction 2 Electric motor thermally stopped
Observation 2
The two LEDs D1 and D2 are on, during and after a shutdown of the motor for a
minimum of 2 minutes (blink code 1.3).
Cause 1
If the temperature in the electric motor becomes higher than 150 °C the system
will be thermally stopped.
Solution 1
Set the manual-control switch to position “0” to erase the error message. When
this occurs again and again or if the error message does not erase, contact your
supplier.
Malfunction 3 A safety stop of the electric motor occurred
Observation 3
The red LED (D2) blinks while the green LED (D1) is on (blink code 1.4).
Cause 1
The duty switch is possibly not disconnected. The electric motor subsequently
operated the safety switch.
Solution 1
Set the manual-control switch to position “0” to erase the error message. When
this occurs again and again or if the error message does not erase, contact your
supplier.
Malfunction 4 Phase failure
Observation 4
The red LED (D2) blinks while the green LED (D1) is off (blink code 1.5).
Cause 1
A phase failure is detected.
Solution 1
Make sure that all phases are connected correctly. Make sure that the connection
terminals have a good connection.
Ridder Drive Systems B.V.