6.3 Operation
This section tells about the operating functions of the RMC400 control-unit:
•
With a built-in manual control (MC) and connected to an automatic control-system (ACS)
•
Without a built-in manual control (MC) and connected to a Ridder manual control (MC) (277950)
and an automatic control-system (ACS).
Always refer to the related information and manuals (ACS and MC).
Before you use the manual control, make sure that the green LED (D1) on control board A2 is on.
If connected, the green LED on the Ridder manual-control must be on at the same time.
Blink code 1.1 gives the indication: No malfunctions, the control unit operates correctly.
Refer to §9.2.
The switch with five positions has the four functions that follow:
1.
The system is manually controlled in direction A or B. The system is controlled independently
also if there is an automatic 24 V AC/DC control signal (ACS).
2.
The system is put in automatic mode.
The system is controlled if there is an automatic 24 V AC/DC control signal (ACS).
3.
The system is manually stopped if the switch is set to position “0”.
4.
The error messages are erased if the switch is set to position “0”.
Function Description
1
Direction A
3
4
The manual control does not control the electric motor.
Position to erase error messages after a malfunction.
0
2
Automatic mode
, the control unit operates when it receives
external control from an ACS.
3
4
The manual control does not control the electric motor.
Position to erase error messages after a malfunction.
0
1
Direction B
RMC400 with MC
LED
Red
LED
Green
OR
OPTIONAL
Ridder Drive Systems B.V.
T
+31 (0)341 416 854 -
F
+31 (0)341 416 611 -
I
24
Ridder Drive Systems B.V.
T
+31 (0)341 416 854 -
F
+31 (0)341 416 611 -
I
25
Содержание MotorControl RMC400
Страница 36: ......