Cable glands
•
Select the necessary number, and location in the bottom of the housing, for the cable glands
M20. Refer to the applicable connections in chapter 5.
•
Drill the holes of ø20 mm and install the cable glands (SW24) with the nuts (SW26).
Note:
Make sure that no damage is caused to the cables and the control board!
Installation
•
Install the RMC400 unit with four screws or such (maximum ø6 mm/ø11.5 mm) in the mounting
holes. The locations of the mounting holes (recommended for the
IP
protection-rating) are in the
corners of the housing!
5. CONNECT INSTRUCTIONS
Only to approved personnel it is permitted to do the connect instructions.
5.1 Electrical material
A minimum conductor diameter of
1.5 mm²
is applicable to the cables in the wiring diagrams. For
the used components, electrical material and cable lengths the necessary conductor diameter can
be different.
272033 (5x)
ø20
mm (5x)
28 mm < Y < 40.5 mm SW=24 mm (5x)
272031 (5x)
SW=26 mm (5x)
Cables!
Control Board !
Y
Y
< ø11.5 mm (4x)
< ø6 mm (4x)
Use only applicable components and electrical material. Always refer
to the related information and manuals.
Ridder Drive Systems B.V.
T
+31 (0)341 416 854 -
F
+31 (0)341 416 611 -
I
14
Ridder Drive Systems B.V.
T
+31 (0)341 416 854 -
F
+31 (0)341 416 611 -
I
15
Содержание MotorControl RMC400