4-A
Connect the reference monitoring to connection 2 of X7. Go to step 5.
Control-board A2
4-B
Connect the reference monitoring to connection 3 of X7. Go to step 5.
Control-board A2
5
The RPU is prepared to set the end positions.
Refer to the RPU product manual at
5.12 OPTIONAL - Alarm (AL)
The RMC400 control-board (A2) has an output for a fault contact (X5) that opens when a random
fault occurs. You can include this fault contact in an alarm circuit.
You can connect one or more control units to an alarm circuit.
Connecting - One RMC400 control-unit
Obey the diagram that follows to connect one control unit.
Connecting - Two or more RMC400 control-units
Obey the diagram that follows to connect the fault contacts (X5) to two or more control units.
It is only permitted to connect the RPU reference-input to X7 of the
control board (A2). Do NOT connect it to the RSU/RLS. Refer to §3.5
(Technical specifications) of X7 and X9.
Control-board A2
Alarm
AL
Control-board A2
Control-board A2
Control-board A2
Alarm (AL)