5.11 OPTIONAL - Position Feedback (RPU)
You can connect a digital positioning-meter (RPU) and an automatic control system (ACS) to the
RMC400 control-unit.
Refer to the diagram ① and procedure ② that follow and connect the RPU. Also refer to the
product manual of the ACS that is used.
① Connecting - Power supply and feedback
•
Connect the 24 V power supply (connection 1 and 2) to connector X7 of the control board (A2)
(connection 1 and 4).
•
Connect the position feedback (connection 3 and 4) to the automatic control-system (ACS).
•
Make sure that the power supply is 24 V
DC
from an external source.
② Check - Reference-input RPU
•
Connect the reference input (connection 5) to use reference monitoring and to set the reference
again. Obey the procedure to connect the RPU connector X7 correctly.
u
Description
1
Select which duty switch (ES11 or ES12) you want to use as switch for the RPU reference-
monitoring. Let the motor turn in the direction of this duty switch until it disconnects.
To prevent damage or injury, do not go across the limit positions of
the operated system!
2
LED D3
or
D4 will come on on control-board (A2). Obey the instructions in 3-A
or
3-B.
3-A
Blink code is 2.1. The LED D4 (RPU CAL. A) comes on.
Refer to §6.2 and §9.2.
Go to step 4-A.
3-B
Blink code is 2.2. The LED D3 (RPU CAL. B) comes on.
Refer to §6.2 and §9.2.
Go to step 4-B.
Control board A2
24 V
DC
4-20 mA
Ridder Drive Systems B.V.
T
+31 (0)341 416 854 -
F
+31 (0)341 416 611 -
I
22
Ridder Drive Systems B.V.
T
+31 (0)341 416 854 -
F
+31 (0)341 416 611 -
I
23
Содержание MotorControl RMC400
Страница 36: ......