Item
Explanation
Around the
Drum
Charge Wires/
Wire Cleaner/
Charge Grid
Dirty charge wires may cause uneven image density.
They should be replaced at regular intervals.
End Blocks
Toner tends to accumulate on the corona end
blocks, this can result in a high voltage leak. Clean
end blocks at regular intervals.
Drum Grounding
Terminal
Too much drum grounding terminal deterioration
causes poor drum grounding. This results in dirty
backgrounds and drum potential sensor calibration
errors.
QL
If toner accumulates on the QL, a dirty background
or a repeating negative image may result.
Clean the QL at regular intervals.
PTL
If paper dust or toner accumulates on the PTL filter,
its efficiency may be reduced. This can cause toner
to be reattracted to the drum during transfer,
reducing image density. Clean the PTL filter at
regular intervals.
ID Sensor
If too much paper dust or toner accumulates on the
ID sensor, the toner density cannot be controlled
correctly. This results in light copy or over toning.
Clean this sensor at regular intervals.
Erase Lamp
If toner accumulates on the erase lamp, a dirty
background may occur in the erased area that
becomes progressively worse in long copy runs.
Also this affects sensor pattern detection, causing
incorrect toner density and exposure lamp control.
Clean this lamp at regular intervals.
Cleaning Blade
A dirty or worn out cleaning blade will cause black
lines on copies or scratches on the drum. The blade
must be replaced at regular intervals.
Cleaning Brush
A worn out cleaning brush will not clean the drum
surface effectively, resulting in a dirty background
and damage to the cleaning blade. Replace at
regular intervals.
Toner Collection
Bottle
If the toner collection bottle becomes full, a service
call condition occurs and copying is prohibited.
Empty the toner collection bottle at regular intervals.
Pick-Off Pawls
After long usage, the point that touches the drum
becomes worn and the area contacting the drum is
increased. This may cause drum filming, resulting in
vertical gray lines on the copy image.
Development
Unit
Developer
The tribo-chargeability of overused developer
decreases. This results in toner scattering.
Developer must be replaced at regular intervals.
Bias Terminal
Less lubricant increases the friction between the bias
terminal and the bias receptacle. This may
deteriorate the terminal.
Rev. 7/94
A095/A096/A097
4-66
FSM
Содержание A095
Страница 1: ...SERVICE MANUAL PN RCFM6655 A095 A096 A097 RICOH GROUP COMPANIES ...
Страница 2: ...SERVICE MANUAL A095 A096 A097 RICOH GROUP COMPANIES ...
Страница 3: ......
Страница 4: ...A095 A096 A097 SERVICE MANUAL PN RCFM6655 ...
Страница 5: ......
Страница 7: ......
Страница 9: ......
Страница 23: ......
Страница 27: ......
Страница 28: ...OVERALL MACHINE INFORMATION ...
Страница 29: ......
Страница 34: ...COMPONENT LAYOUT AND DESCRIPTION ...
Страница 35: ......
Страница 51: ......
Страница 52: ...INSTALLATION ...
Страница 53: ......
Страница 75: ......
Страница 76: ...SERVICE TABLES ...
Страница 77: ......
Страница 143: ...This page intentionally left blank B A095 A096 A097 4 64 FSM ...
Страница 150: ...REPLACEMENT AND ADJUSTMENT ...
Страница 151: ......
Страница 227: ...This page intentionally left blank B Rev 7 94 A095 A096 A097 5 74 FSM ...
Страница 281: ...This page intentionally left blank B Rev 7 94 A095 A096 A097 5 122 FSM ...
Страница 302: ...TROUBLESHOOTING ...
Страница 303: ......
Страница 347: ......
Страница 348: ...DUAL JOB FEEDER A376 ...
Страница 349: ......
Страница 382: ...SORTER STAPLER A377 ...
Страница 383: ......
Страница 417: ......
Страница 418: ...RECIRCULATING DOCUMENT HANDLER A378 ...
Страница 419: ......
Страница 441: ......
Страница 442: ...FINISHER A379 ...
Страница 443: ......
Страница 465: ......
Страница 466: ...LARGE CAPACITY TRAY A380 ...
Страница 467: ......
Страница 486: ...SORTER STAPLER A374 ...
Страница 487: ......
Страница 516: ...TECHNICAL SERVICE BULLETINS ...
Страница 517: ......