北京锐志天宏科技股份有限公司
Beijing RichAuto S&T Co., Ltd.
Forging ahead, create future together!
57
Assertion error (occurred during the processing or after starting) is generally a
software problem. User can boot the controller by entering “emergency state”, or
re-
upgrade it. If can‟t be solved either, user should send back it for repairing.
Unable to read U flash disk or read error occurs
1)
Processing by U-disk, scre
en shows “there is no item in this option”. Format U-disk to
FAT32, change allocation unit to the default configuration size. Then re-import
processing files, it will read normally.
2)
U flash disk capacity is too large (16G, 32G or 64G etc.). Recommend replace U
disks such as 2G ,4G, 8G.
3)
There is something wrong with USB communicate port or U-disk interface is broken,
change a new USB port or U-disk.
4)
There is no any reaction while insert into the U-disk. Change a genuine brand of
U-disk, such as SanDisk, FOUNDER U-disk etc.
5)
If the U-disk interface is weak connection, user can copy files into inner memory
space of the controller for temporary solution.
6)
Program contains non-standard G codes, or some illegal characters. The system
does not recognize them and interrupt handling. Recommend using professional
simulation software to review the program whether there is an illegal character.
Delete all illegal characters.
PS2.2 FAQ in practical operation
After the machining, the cutting size doesn’t match the actual size in processing file
1)
Pulse equivalent is wrong.
2)
User has selected the wrong tool bit which is not the same as it set in process file.
3)
Check if there is any problem with the path processing file.
The screen displays “exceed limit” during processing