北京锐志天宏科技股份有限公司
Beijing RichAuto S&T Co., Ltd.
Forging ahead, create future together!
37
Manual trigger the corresponding signal, the corresponding signal
changed from L
to H means the signal is in normal status
. If not, it is abnormal. User should check the
corresponding switch, wiring and 50 pins cable.The screen will displays as follow.
To trigger X1 (X axis HOME switch), the corresponding letter changed, means X1
signal is normal, X2 to X8 detecting are in the same way.
Note
: Do not confuse with “Voltage setup”.
2
)
OptCheck (Manual test input port)
In the bottom row, the former 4 numbers
1
,
2
,
3,4
corresponding to Spindle ON/OFF,
Multi-speed 1, Multi-speed 2, Multi-speed 3;
The number 5 and 6 are respective to alarm lamp, run lamp. The number 7 and 8 are
user definable output signals. The port definitions will be a little different in individual
custom system.
Manually control the corresponding output port by pr
essing “
” to change the
corresponding letter to H. For example, press “
” to highlight number 1 position to
start
the spindle, then press “
” again to stop the spindle.
3
)
Volt Lvl (Voltage Setup)
Used to set the input, output signal port normally open or normally closed port state,
system defines “
↓
” as normal open; “
↑
” as normal closed.
Including 2 rows of arrows: