does not recognize, interrupt handling. Recommend using professional simulation software to
view the program whether there is an illegal character. Delete all illegal characters.
9.7.2
Faults in practical operation
1.
The file size does not match the size of the actual set
1)
Pulse equivalent is wrong.
2)
You does not select the right tool.
3)
Check the processing file.
2.
The screen displays“beyond limit”druing processing
1)
The machine is not carried back to zero,the system is not able to confirm the actual
position. Make the machine back to zero.
2)
After setting the working origin, the reserved range is less than the actual file size.Confirm
the actual file size and set correct working origin.
3)
You set the wrong working origin in the file. Check the path of the file, and re-export the
correct file.
3.
Hard limit false triggering
1)
System has connected with hard limit signal
:
maybe hard limit switch is broken or voltage
setup X6(X7-A18) is wrong.
2)
System has not connected with hard limit signal
:
confirm that whether connect other signal to
hard limit X6(X7-A18),if not,check voltage setup normal or not,if normal,MACHINE
SETUP-Input Confi-disable X6(X7-A18), then wipe cache and system upgrade.
4.
Z axis
(
spindle
)
fall down abnormally
(
too fast
)
during processing
1)
Working speed beyond the fastest speed of Z axis. " MACHINE SETUP " - " Max Spd Limit
"
,
set the safe speed.
2)
Coupling is loosing or transmission slippages. Re-adjustment the connecting parts.
3)
The lines connect the interface board with the motor drivers has disruption. Re-adjust the
lines.
4)
Processing file error. Check processing file, try to download the correct processing file to U
disk or handle internal.
5)
There is something wrong with the lines connectting Z axis motor and motor driver. Replace
the lines.