Beijing RichAuto S&T Co., Ltd.
Forging ahead and determined to win 12
3.3
Hardware wiring
Installation Requirements
:
Power
(
24V
,
3A
)
,
it is better to add a filter to prevent the electric
field interference.If choosing origin detecting switches of different power supply type, the special
testing switching power is needed.
(
24V origin detecting switch is the best choice
)
RichAuto control system realizes its control through the connection between the interface
board and CNC machine. Interface board terminal can be divided into input terminal and output
terminal
Input terminal
:
INPUT SIGNAL DC24V(Power Supply)
Output terminal
:
X,Y,Z,C axis pulse signal output terminal,OUTPUT SIGNAL
Input terminal
Power Supply
INPUT SIGNAL
1.
Machine Origin
Y and Z are the same as X
Mechanical
NPN
(NO)
PNP(NO)