The signal cable of tool sensor connects to X4(X5-A18), alligator clip connects to
GND-INPUT SIGNAL.
(
alligator clip also can be cliped on the spindle if the spindle connected to
GND
)
Place tool sensor onto workpiece,move Z axis to the upper side of the tool sensor in manual
mode,and press ―
‖+―
‖ to start Z-axis automatic tool setting,the system will
automatically set the workpiece origin of Z axis.
Mobile calibration usually use simple tool sensor which is affordable, easy and convenient.
Precautions
:
Do not rush to make the alligator cliped to the spindle, start the function of tool setting
firstly,and then use the alligator clip to touch the spindle,confirm that Z axis tool setting functcan
is carried out normally.
C.A.D. Thickness system default is 0,user need to set it in ―MACHINE SEUTP- C.A.D.
Thickness‖according to actual value
.