Abnormally working when processing or the actual file is different from theoretical file
1)
The system disorder.
。
2)
Too much external interference.Refresh connection. (Separate low voltage from high voltage,
"GND" of inverter separated from the other components ).
3)
There is something wrong during the process of ENG change to NC.
9.
Start automatic tool setting, the tool does not stop after touching C.A.D(Tool sensor).
1)
Cutter signal cable connects X4(X5-A18) not well.
2)
The "GND" terminal of interface board does not connect with spindle shell or connect not
well.
3)
MACHINE SETUP-Input Confi,confirm that X4(X5-A18) enable.
10.
Coordinate value changes changes, the machine does not move
1)
If one axis is not moving, it may be a connection problem.
Change another normal terminal
to this terminal,if it is ok,the motor dirver is ok.Maybe there is something wrong with
interface board
、
50-pin cable. If it is still not moving, it is necessary to detect the
corresponding drive and motor.
2)
If all axises are not moving ,firstly check if there are problems in the 50-pin cable and
interface,secondly check the power supply of the motor drivers.
3)
Check the mechanical parts.
11.
It is normal to the move from one position to another position, but when return from
that position to the original position is not normal
Mechanical problems
,
screw may install not well.
12.
Direction of movement is wrong
1)
Exchange A+&A-/B+&B- cable of stepper motor
2)
Change motor direction mask(not recommended)
13.
The machine vibrates when arc or two-axis linkage movement
1)
Check whether the machine is placed horizontally
,
2)
Check coupling member loose or not.
3)
Increasing the start speed, avoid the resonance point.