Beijing RichAuto S&T Co., Ltd.
Forging ahead and determined to win 61
2.
Parameter setting
DELTA
ASDA-B2
Function
Value
Description
P1-00
External pulse train
input type
102
Bit 0
:
2--pulse+direction
Bit 2
:
1--negative logic
*P1-01
Set control mode
0000
Bit 3
:
Maintaining the set value.Since switching
control mode is not used,bit 3--0.
Bit 2
:
0--forward rotation(CCW)(from the view of
load)
Bit 1,0
:
00--position control mode
P1-44
Electronic gear
ratio(numerator)(Z1)
Need
calculation
Range
:
1~32767
;
Z1 =Encoder pulses×4
;
Z2 =Pulse equivalent×Screw pitch×Transmission
ratio
e.g. Pulse equivalent 1000
,
Screw pitch 10mm,
encoder pulses 40000
,
Transmission ratio 1
Pn1-44/Pn1-45=40000×4/1000×10×1=160000/10000
=16/1
P1-45
Electronic gear
ratio(denominator)
(Z2)
Need
calculation
P2-10
Function setting for
digital input pin DI1
1
Bit 0
:
Set 1,servo on all the time.
P2-18
Function setting for
digital output pin
DO1
108
DO1 corresponds to pin-6 & pin-7,used as
clamping-position brake signal of Z-axis
Bit1,0
:
08--set pin-6 and pin-7 as BK- and BK+
repectively.
Bit2
:
0--set DO15 output as normally closed
b-contact point
P2-22
Function setting for
digital output pin
DO5
007
DO5 corresponds to pin-28 & pin-27,used as servo
alarm signal
Bit1,0
:
07--set pin-28 and pin-27 as ALRM+ and
ALRM- repectively.
Bit2
:
0--set DO5 output as normally closed b-contact
point