4.0
Configuration
There are two types of configuration parameters in the 680, setup mode parameters (or Legal for Trade configuration) and user
mode parameters (or non-legal configuration). Setup mode parameters are accessed by pressing the setup switch (
).
User mode parameters are accessed by pressing the menu button and do not require pressing the setup switch.
The following sections provide graphic representations of the 680 menu structures. Most menu diagrams are accompanied by a
table which describes all parameters and parameter values associated with the menu. The factory default setting appears at the
top of each column in bold type.
The audit, setpoints, accumulator, tare, time, date, Mac ID and version menus can be accessed by pressing
.
The top-level setpoints menu displays the setpoint value of configured setpoints and is accessible with the menu
button. Complete configuration of setpoints is under the setup menu and requires the setup switch for access.
The setup menu are accessed by pressing the setup switch (
).
A
ll weight related parameters must be configured prior to calibrating the unit.
4.1 Setup Switch
In order to configure the 680, it must be placed in setup mode with the setup switch. The setup switch is accessed through a
small hole on the bottom of the enclosure. Remove the setup switch screw and insert a non-conductive tool into the access hole
to press the setup switch.
Use caution when inserting the non-conductive tool into the enclosure. Insert the tool about 3/4'' (19 mm), until
the switch is engaged. Do not use excessive force which could damage the switch.
Figure 4-1. Setup Switch Access
When the 680 is placed in setup mode, the setup menu is accessed and
config
displays. See
detailed breakdown of this menu. Torque the setup switch screw to 10 in-lb (1.1 N-m) when reinserting.
4.1.1 Audit Jumper
The audit jumper (J24) turns setup mode access on and off. Access to setup mode is allowed without pressing the setup switch
when the audit jumper is in the on position. Access to setup mode requires pressing the setup switch when the audit jumper is in
the off position. See
for the location of the audit jumper on the CPU board.
In certain Legal for Trade applications it is necessary to seal the indicator to restrict access to the setup switch
(
). Breaking of the seal terminates the Legal for Trade status of the indicator.