EDP Commands
© Rice Lake Weighing Systems
●
All Rights Reserved
51
7.11 Print Format Commands
7.12 Digital I/O Commands
7.13 Analog Output Commands
Command
Description
Values
GFMT
GFMT.PORT
GFMT.PORT2
Gross demand print format string
Each format can be sent out one or two ports; for the .PORT and .PORT2 commands,
specify the port name as one of the following: RS232-1, RS232-2, RS485, TCPC, USB,
NONE
Example: To send the Gross format out both RS-232 Port 2 and the TCPC Port at the same
time, send:
GFMT.PORT=RS232-1
GFMT.PORT2=USB
for information about demand print format strings
NFMT
NFMT.PORT
NFMT.PORT2
Net demand print format string
ACCFMT
ACC.PORT
ACC.PORT2
Accumulator print format string
SPFMT
SPFMT.PORT
SPFMT.PORT2
Setpoint print format string
HDRFMT1
HDRFMT2
Ticket header format strings
AUD.DEST1
AUD.DEST2
Audit trail port
Table 7-11. Print Format Commands
Command
Description
Values
DIO
.b
#
s
Sets DIO type
OFF
(default), OUTPUT, PRIM, PRINT, SEC, TARE, UNITS, ZERO, BATRUN,
BATSTRT, BATPAUS, BATRESET, BATSTOP, CLEAR, CLRACC, CLRCN, CLRTAR,
DSPACC, DSPTAR, GROSS, KBDLOC, NET, NT/GRS
Valid bit values (
b
) are 1-4; For commands ending with
#s
, s is the slot assigned to the digital I/O (0); Slot 0 is onboard
Table 7-12. Digital I/O Commands
Command
Description
Values
ALG.SOURCE#
s
Analog output source
SCALE1
(default), REMOTE
ALG.MODE#
s
Mode
GROSS
(default), NET
ALG.OUTPUT#s
Type of output
0-10V
(default), 0-20MA, 4-20MA
ALG.ERRACT#
s
Error action
FULLSC
(default), HOLD, ZEROSC
ALG.MIN#
s
Minimum value tracked
±9999999.0,
0.0
(default)
ALG.MAX#
s
Maximum value tracked
±9999999.0,
10000.0
(default)
For commands ending with
#n
, n is the slot number assigned to the analog output (1)
Table 7-13. Analog Output Commands