Installation
© Rice Lake Weighing Systems
●
All Rights Reserved
7
2.4.2 Torque Ratings
Refer to
throughout installation and use of product to maintain proper torque ratings for 680 components.
2.4.3 Load Cell Cables
To attach the cable from a load cell or junction box, route cable to the J1 connector (
). Connector for the
cable is included in the parts kit. See
for wiring the load cell cable from the load cell or junction box to connector.
A ferrite from the parts kit must be applied to the load cell cable within 1'' (25 mm) of the load cell. The cable must be
sent through the ferrite twice.
For a 4-wire installation leave pins 3 and 4 empty on the connector.
For a 6-wire installation set the SENSE parameter to 6-WIRE in the CONFIG menu (
).
2.4.4 RS-232 Serial Communications
The J3 connector (
) is intended to provide a connection point for the RS-232 serial communications.
Two RS-232 ports are available. See
for the pin assignments for the J3 connector.
2.4.5 RS-485/422 Serial Communications
The J4 connector (
) is intended to provide a connection point for the RS-485/422 serial communications.
See
for the pin assignments for the J4 connector.
For transmit connections TXZ = TDB and TXY = TDA.
Component
Torque Rating
Backplate Screw
15 in-lb (1.7 N-m)
Setup Screw
10 in-lb (1.1 N-m)
Cord Grip Nut (to enclosure)
33 in-lb (3.7 N-m)
Cord Grip Dome Nut (around cable)
22 in-lb (2.5 N-m)
Table 2-2. Component Torque Ratings
Connector
Pin
Function
J1
1
+SIG
2
–SIG
3
+SENSE
4
–SENSE
5
+EXC
6
–EXC
Table 2-3. J1 Pin Assignments (Load Cell)
Connector
Pin
RS232-1
RS232-2
J3
1
GND
–
2
RX1
–
3
TX1
–
4
–
GND
5
–
RX2
6
–
TX2
Table 2-4. J3 Pin Assignments (RS-232)
Connector
Pin
RS485
422/485 Adapter
J4
1
GND
GND
2
RXB
TDA(-)
3
RXA
TDB(+)
4
TXZ
RDA(-)
5
TXY
RDB(+)
Table 2-5. J4 Pin Assignments (RS-485/422)