Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
39
4.4.10 Setup – Analog Output Menu
Figure 4-21. Setup – Analog Output Menu
4.5 Accumulator Menu
Figure 4-22. Accumulator Menu
4.6 Tare Menu
Figure 4-23. Tare Menu
Parameter
Description
source
Source – Specifies the scale tracked by the analog output;
Settings:
GROSS
(default), NET
output
Output – Specifies the voltage or current tracked by the analog output;
Settings:
0-10V
(default), 0-20MA, 4-20MA
erract
Error Action – Specifies how the analog output responds to system error conditions;
Settings:
FULLSC
(default)
– Set to full scale (10 V or 20 mA)
HOLD
– Holds current value
ZEROSC
– Sets to zero value (0 V, 0 mA or 4 mA)
min
Minimum Weight – Specifies the minimum weight value tracked by the analog output;
Enter value: ±9999999.0,
0.0
(default)
max
Maximum Weight – Specifies the maxmum weight value tracked by the analog output;
Enter value: ±9999999.0,
10000.0
(default)
Table 4-18. Setup – Analog Output Menu Parameters
Parameter
Description
dispacm
Display Accumulator – Displays the accumulator value;
Read Only
prtacum
Print Accumulator – Prints the accumulator value to specified port, if setup
clracum
Clear Accumulator – Clears the accumulator value
Table 4-19. Accumulator Menu Parameters
Parameter
Description
disptar
Display Tare – Displays the current tare value;
Read Only
clrtare
Clear Tare – Clears the current tare value
Table 4-20. Tare Menu Parameters
Setup
ALGOUT
OUTPUT
ERRACT
MIN
MAX
SOURCE
ACCUM
dispacm
prtACum
CLRACum
TARE
disptar
CLRTARe