TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions
REV: AA Issued: 22/02/17
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
5
Component Specifications
Resistance value tolerances ±10%.
Specification
834012N0
834012P0
834016N0
834016P0
Water Flow Sensor
Pulses voltage supplied from temperature control
according to water flow rate
21 Hz @ 3.01 L/m, 74 Hz @ full flow rate
Hydro Electric Generator (G)
Generates 1.1 ~ 1.7 VDC
(8 ohms: white wire to white wire)
Water Throttle Valve (WV)
Start voltage
≥ 2.4 VDC, hold in > 0.32 VDC
(8 ohms: white wire to white wire)
Gas
Valve
SV1 (pilot valve)
Ignition voltage > 0.9 VDC, hold in > 0.1 VDC
(40 ohms: orange wire to earth)
SV2 (main burner safety valve)
> 0.9 VDC (60 ohms: green wire to earth)
SV3 / MASV
(4)
SV3
> 0.6 VDC (100 ohms: green wire to earth)
MASV
> 1.2 VDC (8 ohms: red wire to black wire)
Yellow wire output motor operation pulse check
Hot Water Outlet Temperature Sensor
For temp/resistance chart refer to ‘Testing the Hot
Water Outlet
Temperature Sensor’ on page 39
Overheat Protection
Software
Hot water outlet temperature shut down @ 85°C
Overheat Switch
Contacts open @ 95°C ± 4.5°C
manual reset
@ ≤ 90°C
Ignition Module
Model
P700 (refer to 'Ignition Module' on page 19)
Flame Sensitivity
> 0.5 µA. Normal flame generation 2 ~ 10 µA
(2 µA @ min fire, 10 µA @ max fire)
Temperature
Controller
Model
AT102-RH
Battery
3.7 VDC lithium ion rechargeable 600 mA/h
DIP Switches
Refer to 'DIP Switch Adjustments' on page 45
Min & Max Dials
Refer to 'Checking & Adjusting Burner Gas
Pressure' on page 47
Ignition Rod
3.5 ~ 4mm gap. Refer to 'Adjusting the Ignition Rod
Gap' on page 46
Flame Sensor
Refer to 'Adjusting the Flame Sensor' on page 46
Burner Injectors
Quantity
14
14
18
18
Orifice diameter
1.3 mm
0.8 mm
1.3 mm
0.8 mm
Inlet Water Strainer
Accessed by removing cold water inlet drain plug
(4)
SV3 / MASV = Motor Adjustable Solenoid Valve (gas flow rate control) for main burner.