TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions
REV: AA Issued: 22/02/17
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
29
Fault Finding Chart 1
YES
Refer to fault finding chart for
the fault indication displayed.
1
YES
Do temp controller
LED’s indicate a fault
condition?
Heater not operating
Are all wiring plugs
and wiring connectors
firmly connected?
YES
NO
Is water flow rate
through heater
> 3 L/m?
NO
NO
1.1
Firmly connect wiring
connector(s) and/or plug(s).
Are hot tap(s) opened
enough?
Hot tap(s) must be opened
enough i.e. water flow rate
through the heater must be
> 3 L/m.
NO
Is cold water isolation
valve fully open?
YES
Advise customer that water
supply pressure is not within
specification.
NO
Minimum water supply
pressure is 150 kPa.
Is water supply
pressure adequate?
Fully open cold water isolator
located adjacent to heater.
NO
YES
Is water inlet strainer
blocked?
Clean or replace water inlet
strainer.
YES
YES
Is hydroelectric
generator / water flow
sensor assy blocked?
Unblock hydroelectric
generator / water flow sensor
assembly.
NO
YES
Is cold water inlet /
seasonal adjustment
valve assy blocked?
YES
NO
Is water throttle valve
assy blocked?
Unblock or replace cold water
inlet / seasonal adjustment valve
assembly.
Unblock or replace water throttle
valve assembly.
NO
YES
Is hot water outlet
assy blocked?
Unblock or replace hot water
outlet assembly.
NO
YES
Unblock or replace blocked heat
exchanger.
Is pipework to and
from heat exchanger
blocked?
Unblock or replace blocked
pipework.
NO
YES
NO