TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions
REV: AA Issued: 22/02/17
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
24
Fault Finding Chart
– Red LED 2 Flash Indication
Red LED 2 Flash
Ignition module circuit abnormal
Are all wiring plugs
and wiring connectors
firmly connected?
YES
NO
Firmly connect wiring
connector(s) and/or plug(s).
Replace ignition module
NO
Fault rectified.
Replace temperature controller
and reinstall original ignition
module.
Does red LED 2 flash
fault indication
persist?
YES
Fault Finding Chart
– Red LED 3 Flash Indication
Red LED 3 Flash
MASV faulty
Are all wiring plugs
and wiring connectors
firmly connected?
YES
NO
Firmly connect wiring
connector(s) and/or plug(s).
Replace temperature
controller
NO
Fault rectified.
Replace gas valve assembly
and reinstall original
temperature controller.
Does red LED 3 flash
fault indication
persist?
YES
Is SV3
resistance ok?
(TEST 3)
Is MASV
resistance ok?
(TEST 4)
YES
Replace gas valve assembly.
NO
NO
YES