TM081 Rheem 834 Series Hydroelectric CFGWH Service Instructions
REV: AA Issued: 22/02/17
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed uncontrolled.
22
Fault Finding Charts
Fault Diagnosis Sequence (General Fault Finding Chart)
What is complaint?
YES
GENERAL FAULT
FINDING CHART
4
Water not hot enough
Leaking heater
Noisy heater
Does the temperature
controller red LED
indicate a fault when
water is flowing
through the heater?
2
3
Water flow rate through the heater must be > 3 L/m for the water heater to operate.
1
Heater not operating
5
Water too Hot
NO
Refer to fault finding chart for
the fault indication displayed.
Does the temperature
controller green LED
continuously flash
when water is flowing
through the heater?
NO
Refer to ‘Fault Finding Chart –
Green LED Continuously
Flashing’.
YES
Refer to 'Operational & Fault Indication' on page 21 for fault indication fault finding chart indexes.