44
Fault Finding Tests 14
Test 14
Using a digital multimeter set on the frequency (Hz) scale, measure between wiring pin 8
(orange wire) and wiring pin 9 (orange wire) on the temperature controller 16 pin plug.
The following result should be obtained when
water flow through the heater is > 3
L/m
:
21 ~ 74 Hz (21 Hz @ 3 L/m, 74 Hz @ full flow rate).