connessioni
by
MAN1920124 rel. 01 dated 23.09.2011
page no. 24 of 48 pages
07.
connections
07.01. water
07.02. energy
make sure that the water used to supply the vending machine has
all proper features for human consumption;
make sure that there is no sign of impurity and check the degree of
hardness; if necessary, contact an analysis lab;
if necessary, use a softening filter and replace the cartridge at
regular intervals to preserve the machine components;
make sure that the network pressure is the one preset for the
machine (see 03.03.); use a pump or a reducer in case of non-
compliance; it is recommended to install a tap to detach the
machine from the network; connection shall occur by means of a
tube type-approved for food use and capable of supporting the
operating pressure; if the machine is supplied by an internal water
tank, make sure that the tank is properly positioned in its seat and
fill it;
for the drinkability features of “waters intended for human
consumption” refer to the following Internet address:
http://eur-lex.europa.eu/
directive 98/83/EC of 03/11/1998
observe the rules on connections with the electric network, in
particular on grounding; connect the machine permanently without
using any reduction, adaptor, multiple socket or extension; use the
network connection cable supplied with the vending machine only;
it is recommended to install a switch detaching the machine from
the network;
it is recommended to install a differential current device operating
below 30 mA, detaching the machine from the mains and promptly
tripping in case of improper electric input in order to considerably
reduce the risks arising out of any short-circuit;
attention
check the power plant capacity to supply the power required by the
machine (see 03.03) and the observance of the rules in force;
strictly refer to the data of the serial number label (see 02.04.)
insert the cable into the connection socket (see 05.07.); then,
connect the plug with the socket and supply the vending machine;
for a correct and safe configuration of the electric power supply
installation refer to the following Internet address, if necessary:
http://eur-lex.europa.eu/
directive 2006/95/EC of 12/12/2006
Содержание barista XX