4.5.18
Delay for 2nd clipper pulse
This is for setting the time delay after the end of the 1st clip-
per pulse for the start of the 2nd clipper pulse. The 2nd clip-
per pulse is set only if the 2nd clipper pulse function is acti-
vated. The duration of the 2nd clipper pulse is equal to the
duration of the 1st clipper pulse.
4.5.19
Start before/after beginning filling
It’s possible to determine here when the second machine
should be started after beginning the filling (adjustment range
of –9999, 9 to 9999, 9 cm³)
i.e. adjustment: > 5 cm³, now the second machine would start
5 cm³ after starting to begin filling.
4.5.20
Stop before/after end of filling
It’s possible to determine here when the second machine
before should be stopped before the end of the filling (ad-
justment range of –9999, 9 to 9999, 9 cm³)
i.e. adjustment of 5 cm³ > the second machine would now
stop 5 cm³ before the end of filling.
4.5.21
Beginning the second portion
It’s possible to determine here whether the start of the second
machine is active already before the first portion or if the sec-
ond machine should be started only after the second portion
(adjustment range on/off.).
4.5.22
Weighing system
Open the settings input mask here, if the REX filling machine
is connected to an external weighing terminal - see 4.21
Weighing system
4.5.23
Moving at a certain speed
Here you may select whether the speed on the main input
mask screen is displayed in pieces per minute or in %.
4.5.24
Metal detector
A window for the settings parameters will open when activat-
ed - see 4.20 Metal detector