RVF 327, 327 S, 330, 330 S
ex no. 1200
Maintenance
Version 1.5
page 125 of 144
-
Rinse off all cleaning solvent handled parts with ca. 60-70°C warm wa-
ter of drinking quality. For this a high pressure cleaner, low pressure
cleaning device, spray pistol or water hose is used. Meanwhile, however,
all safety precautions in this chapter must be absolutely adhered to!
-
Check all cleaned parts for absolute cleanliness through certain visual
inspection. Repeat the cleaning measures if any product remains are not
removed!
-
Disinfecting all handled parts with a disinfectant solvent according to
cleaning plans and with the necessary tools (high pressure cleaner, low
pressure foaming machine, spray gun, brushes etc.).
The effectiveness time on the product data sheet of the manufacturers of
cleaning and disinfectants, and other usage instructions must be followed
exactly!
-
Clear rinse all disinfected parts with drinking water.
-
Dry all handled parts (possibly with sterile and oil free compressed air)
-
Oil all handled parts with a care product according to cleaning plan.
Attention: This cleaning and disinfecting work is extremely important for:
Trouble free quality of the product
Avoiding biological un-cleanliness of the product
Fulfilling required hygienic laws
Preserving value of the Vacuum filling machine