RVF 327, 327 S, 330, 330 S
ex no. 1200
Transport, set up, installation
page 30 of 144
Version 1.5
3.8
BEGINNING OPERATION
Electrical connection
Indication sign on the power supply cable must unquestionably be followed!
Indications for the installation and commissioning:
Installations- and commissioning tasks may only be carried out by electrical
specialist personnel or from trusted specialists initiated for this operation,
under observance of the legal and national regulations, i.e. EN 60204.
Protective measures and equipment must correspond with the legal national
standards and norms i.e. EN 50178 and EN 60204
The discharge current can be higher than 3,5 mA AC and higher than 10 mA
DC!
Nominal voltage of the Vacuum filling machine: _____ V
Pre-fusing __________________ A
FI-protective switch
There can be in principle, dependent upon circumstances, the possibility of a problem arising
in connecting the FL protective switch to our Vacuum filling machine. If no avoidance of the
FI-protective switch is possible, then the problem with the on and off switching be deactivat-
ed through the employment of selective FI-protective switches (cut off delay) or FI-protective
switch with increasing release of electricity (z. B. 100 or 300 mA). This can only be put to use
exclusively with all-electric sensitive FI-protective switch. Es is not recommended to have
several machines to operate off of one FI-protective switch.