RVF 327, 327 S, 330, 330 S
ex no. 1200
Maintenance
Version 1.5
page 119 of 144
5.2.2
Chart: Types of material and cleaning procedures
Important cleaning parts and their allowed cleaning procedures
Pos.
Parts names according to
Figure 3, page 24
Material type
Possible cleaning proce-
dures
1 Filling
hopper
Stainless
steel
Alkaloid/acid
Conveyor parts Figure 47, page
97
Stainless steel Alkaloid/acid
Main switch (Figure 9)
plastic
No chemicals
9 Operation
table: keyboard
plastic
plastic
No chemicals
No chemicals
3
Vacuum inspection glass
Plastic
No chemicals
8 Covers
Stainless
steel
Alkaloid/acid
5 Machine
housing
Stainless
steel
Alkaloid/acid
6
Knee lever
Plastic
Alkaloid/acid
5.2.3
Cleaning agents
The use of high pressure cleaners is recommended with the following accessories:
Lanze with full stream nozzle Conveyor system parts
Lanze with wide spray nozzle For machine housing
Attention!
Do not spray the following
parts:
-
Touch-controls
-
Switch
box
-
Electrical
compo-
nent devices
-
mech. Storage
areas
chart,
page 120/121
Container for cleaner
With socket on the device
Cont. for disinfection agent
Disinfection agents