Technical data
34 Operating instructions RLD
ELTROPLAN
-
REVCON
Elektrotechnische Anlagen GmbH
3.3.4
Current load REVCON RLD B0
Note!
To calculate the correct value of regenerating power it is necessary to note, that the real momen-
tary regenerating power is dependent on the real existing main circuit voltage at any time. To
calculate the regenerative power the following formula should be used:
P = U
eff
· I
eff
·
√
3
· cos
ϕ
ϕ
ϕ
ϕ
(during feedback operation cos
ϕ
= 1 is valid)
The maximum possible regenerative power is calculated based on the momentary RMS mains
voltage and the maximum RMS current of the respective device.
For example:
Device type RLD B0 45 with rated feedback power of 45kW, maximum rated RMS current 65A
(refer to technical data), nominal mesh voltage rating e.g. 400V.
From that results: P=400V x 65A x
√
3
=45033W, that’s about 45,0kW
If the momentary RMS mains voltage is only 395V or even lower for a short time, the maximum
possible regenerative power is reduced as well:
P = 395V x·65A x
√
3
= 44470W, that’s about 44,5kW.
Nominal voltage 230V
REVCON
®
- type
AC
Max. current I
rms
[A]
DC
Max. current I [A]
REVCON
®
-
item number
RLD B0 4-230-50-0-A
10
12
21011141
RLD B0 7-230-50-0-A
18
21
21011142
RLD B0 12-230-50-0-A
30
36
21011143
RLD B0 18-230-50-0-A
45
55
21011144
RLD B0 22-230-50-0-A
55
66
21011145
RLD B0 38-230-50-230-A
95
115
21011146
RLD B0 50-230-50-230-A
126
152
21011147
RLD B0 75-230-50-230-A
188
228
21011148
RLD B0 90-230-50-230-A
226
274
21011149
RLD B0 115-230-50-230-A
289
350
21011150
RLD B0 145-230-50-230-A
360
433
21011151
RLD B0 200-230-50-230-A
498
603
21011152
Table 3.3.4.1
Содержание RLD B
Страница 68: ...Installation Operating instructions RLD 67 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 1 Enclosure 0 340...
Страница 69: ...Installation 68 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 2 Enclosure 1 500...
Страница 70: ...Installation Operating instructions RLD 69 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 3 Enclosure 2 700...
Страница 71: ...Installation 70 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 4 Enclosure 3 800...
Страница 72: ...Installation Operating instructions RLD 71 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 5 Enclosure 3 801...
Страница 73: ...Installation 72 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 6 Enclosure 3 802...