Safety information
Operating instructions RLD 19
ELTROPLAN
-
REVCON
Elektrotechnische Anlagen GmbH
Typical capacitance of the DC-connection inside the power feedback unit
:
REVCON
®
-type
Power
[kW]
DC-capacitance
[µF]
RLD B 400V
7
20
RLD B 400V
13
20
RLD B 400V
22
40
RLD B 400V
33
40
RLD B 400V
45
100
RLD B 400V
70
220
RLD B 400V
90
220
RLD B 400V
135
440
RLD B 400V
160
660
RLD B 400V
200
660
RLD B 400V
225
660
RLD B 400V
250
880
RLD B 400V
345
1320
Table 2.6.1
REVCON
®
-type
Power
[kW]
DC-capacity
[µF]
RLD D 400V
11
100
RLD D 400V
18
100
RLD D 400V
28
100
RLD D 400V
38
100
RLD D 400V
50
220
RLD D 400V
70
440
RLD D 400V
100
440
RLD D 400V
135
660
RLD D 400V
160
880
RLD D 400V
200
1100
RLD D 400V
250
1320
RLD D 400V
300
1760
Table 2.6.2
Содержание RLD B
Страница 68: ...Installation Operating instructions RLD 67 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 1 Enclosure 0 340...
Страница 69: ...Installation 68 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 2 Enclosure 1 500...
Страница 70: ...Installation Operating instructions RLD 69 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 3 Enclosure 2 700...
Страница 71: ...Installation 70 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 4 Enclosure 3 800...
Страница 72: ...Installation Operating instructions RLD 71 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 5 Enclosure 3 801...
Страница 73: ...Installation 72 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 6 Enclosure 3 802...