![Renkforce RF2000 v2 BSS Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/renkforce/rf2000-v2-bss/rf2000-v2-bss_operating-instructions-manual_1441509078.webp)
78
• Click the tab "
Manual Control
" on top.
• In the field "
G-Code
", enter "
M3013
" (without the quotation marks)
and click the button "
Send
".
The command "
M3013
" outputs the values of the matrix in steps. If
you use the command "
M3013 P1
" instead, the values are output
in mm.
• The log field now shows the values of the matrix.
• The first series of numbers (;7;0;20;40;...) indicates the position of
the value in the X-direction in mm, with 7 representing the format
of the matrix and not being relevant for the position in X- and Y-
directions.
• The position in the Y-direction is also indicated in mm by the figures
at the beginning of each row of figures (;0;30;50;...).
• Also observe that the value (-772) at the upper left, i.e. in position
X=0 and Y=0, is located at the front left of the printing plate when
looking at the printer from the front left. The value (-628) at the
lower right, in position X=170 and Y=290, is at the rear right on the
heating plate.
• The offset value indicated under the full values (larger, red box), in
-
dicates the lowest value. This then is the position where the nozzle
has the smallest distance from the printing plate. In our example,
the offset value is -588 steps.
• Now find the offset value in your matrix. In our example, the -588
steps are in position X 160 and Y 250. You need to set the nozzle
to 0.3 mm in this position in the next heat bed scan.
• To the right, you can see the matrix again, presented a little better
structured. The Z-offset value -588 is bolded here.
• The values in the matrix can be briefly explained as follows:
The values are indicated in steps. 2560 steps in Z-direction equal
precisely 1 mm. The values indicate the distance between the sur-
face of the heating plate and the trigger point of the Z-limit switch
"Z-Min" (Z home position).
This means that in position X 160 and Y 250, the distance between
the heating plate and the Z Home position is 588 steps.
• If everything is set correctly mechanically, the values in the matrix
must all be negative.
front left
front right
0
20 40 60 80 100 120 140 160 170
0
-772 -808 -836 -832 -860 -872 -888 -916 -964 -964
30
-772 -808 -836 -832 -860 -872 -888 -916 -964 -964
50
-832 -876 -896 -892 -920 -932 -936 -952 -980 -980
70
-920 -964 -988 -972 -980 -980 -972 -956 -984 -984
90
-948 -968 -996 -988 -988 -984 -980 -964 -980 -980
110
-976 -996 -1012 -992 -972 -968 -964 -960 -964 -964
130
-928 -956 -976 -952 -956 -964 -960 -964 -968 -968
150
-912 -928 -916 -892 -908 -904 -892 -900 -900 -900
170
-896 -888 -880 -868 -860 -844 -824 -828 -808 -808
190
-860 -872 -868 -820 -812 -796 -752 -756 -740 -740
210
-888 -884 -872 -824 -796 -744 -704 -696 -672 -672
230
-936 -944 -944 -852 -792 -752 -700 -676 -656 -656
250
-952 -940 -928 -836 -788 -724 -664 -636
-588
-588
270 -1120 -1084 -1028 -936 -868 -800 -736 -668 -628 -628
290 -1120 -1084 -1028 -936 -868 -800 -736 -668 -628 -628
back left
back right