![Renkforce RF2000 v2 BSS Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/renkforce/rf2000-v2-bss/rf2000-v2-bss_operating-instructions-manual_1441509028.webp)
28
Configuration
Feed rate
Max X: 500
Max. speed of the X-axis
Max Y: 500
Max. speed of the Y-axis
Max Z: 50
Max. speed of the Z-axis
Home X: 80
Max. speed of the X-axis when moving to the home position
Home Y: 80
Max. speed of the Y-axis when moving to the home position
Home Z: 10
Max. speed of the Z-axis when moving to the home position
Z Calibration
Scan
Quick printing plate calibration
Scan PLA
Printing plate calibration with typical PLA-temperatures
Scan ABS
Printing plate calibration with typical ABS-temperatures
Align Extruders
Alignment of the two extruders without printing plate calibration
With this point, the two extruders can be aligned subsequently without printing plate scan. The
extruders must be manually heated to the desired temperature.
Z Offset
Shifts the distance between the nozzle and heating plate in Z-direction by the specified value
(standard = 0 µm)
Position Z
Z: 0.00 mm
Moves Z-axis to an adjustable position;
Move with the arrows "
up
"/"
down
" (1)
End stop min: Displays the limit switch condition min. (light barrier)
End stop max:
Displays the limit switch condition max. (bottom at the Y-plate)
Single Move
Switches the length of the movement per push of the button; switch with the
arrow "
right
" (1):
Single Move = Moves until the button is released
1 mm/10 mm/50 mm = Movement by the chosen length in mm
Single Steps = Movement by single steps; 1 push of button = 1 single step
Set Z Matrix: 1
Up to 9 heat bed scans can be saved
Restore Defaults Resets the settings to defaults