UM-B-041
SmartBond Production Line Tool
User Manual
Revision 4.8
02-Nov-2022
CFR0012
12 of 170
© 2022 Renesas Electronics
3
New Version Features
This manual explains the usage of the 16 channels SmartBond
TM
Production Line Tool (PLT). It
refers to the SmartBond_PLT_v5.0 software release, which compared to SmartBond_PLT_v_4.5 has
the differences shown in
Table 1: SmartBond_PLT_v5.0 Added Features
#
Features
Description
1
DA1470x family support
Supports only DA1470x family. The older SmartBond family of
products are supported in previous PLT versions.
2
PCB panel serial number
Before each test a screen prompts user to enter the panel serial
number. PLT will add number 1-16 to the end of the serial number
and append it to each DUT log as shown below for DUTs 10, 11,
12 and 13.
3
OTP configuration script
The OTP CS programming parameters are specific to the DA1470x
product family.
4
OTP configuration script check
empty
Updated operation of OTP CS check empty algorithm.
●
No check:
Check disabled.
●
Error if command exists:
Returns error if the command is
already written in the DUT, even if the data are the same.
●
Skip if entry exist:
Skip writing an entry without error if the
command and the data are already written in the DUT. If same
command is found with different data an error will be returned.
●
Skip if command exists:
Skip writing without returning error if
the command in the DUT OTP CS is already written, no matter
what the data are (same or different).
5
XTAL 32 MHz settle time
calibration.
XTAL 32 MHz. calibration is extended to support settle time
calibration, with values found programed in OTP CS and applied in
XTAL32M_TRIM_REG (0x50050408) DA1470x register. Operation
adds less than 1sec extra delay but has great benefits in overall
product sleep and thus power performance.