Pump and Boiler Logic Module

Instruction Manual

Model No PL07

Salus PL07 Manual Ver007.qxd:Layout 1  10/9/10  10:02

Summary of Contents for PL07

Page 1: ...Pump and Boiler Logic Module Instruction Manual Model No PL07 Salus PL07 Manual Ver007 qxd Layout 1 10 9 10 10 02...

Page 2: ...PL07 INSTRUCTION MANUAL 2 Salus PL07 Manual Ver007 qxd Layout 1 10 9 10 10 03...

Page 3: ...llowed along with any other statutory obligations This accessory must be fitted by a Competent person and installation must comply with the guidance provided in the current editions of BS7671 IEE Wiri...

Page 4: ...esigned specifically for heating applications FEATURES Modular installation Cage clamp wiring terminals no terminal screws Separate circulating pump and boiler control relays Volt free contacts User s...

Page 5: ...continue The PL07 logic module is not a standalone unit and is intended to be mounted on a KL06 wiring centre The wiring centre should be installed first followed by the PL07 logic module To install t...

Page 6: ...lamp terminals on the front of the module after first securing the cable in the KL06 wiring centre PL07 INSTRUCTION MANUAL 6 Terminal Marking Function 1 Common Contact Boiler 2 Normally Open Contact B...

Page 7: ...lease take the following steps to make the wiring connections to the PL07 1 Prepare the cable ends Strip outer sheath to a distance of 110mm Strip 10mm from the ends of each conductor sheath It is ver...

Page 8: ...d 1 0 1 5mm2 If using stranded cable a small screwdriver can be used to open the cage clamp to allow conductor insertion 5 Fit the protective cover Secure the cover by turning the locking screws a qua...

Page 9: ...ont panel When initially powering up the PL07 both LEDs will turn on for about one second before turning off The LED indicators allow the user to see at a glance the current status of the logic module...

Page 10: ...ON Enables boiler and pump protection delays turning on pump and boiler relays for 3 minutes when a thermostat calls for heat J2 Pump overrun Jumper in ON 3 time ON OFF minute position ON After all th...

Page 11: ...ed for Volt free operation and will work with boilers with 24V AC or 230V AC control systems Circulating Pump Control The PL07 will turn the circulating pump on when it receives a signal from any of t...

Page 12: ...t the boiler will be turned off immediately and the pump will be operated in accordance with the relevant jumper settings i e the pump will be turned off immediately or after a delay of three minutes...

Page 13: ...le fail to function correctly check The KL06 wiring centre has mains power The PL07 is inserted correctly into the wiring centre Heating system time switch or programmer is switched on WARRANTY Salus...

Page 14: ...hing Voltage 230V AC 50Hz Switching Current 5A resistive 2A inductive Contact Type Normally Open 2 Boiler Relay Switching Voltage 24V AC or 230V AC 50Hz Switching Current 5A resistive 2A inductive Con...

Page 15: ...PL07 INSTRUCTION MANUAL 15 Salus PL07 Manual Ver007 qxd Layout 1 10 9 10 10 03...

Page 16: ...1226 323961 Email tech salus tech com Tel 01226 323961 Sales Technical Salus Controls plc Salus House Dodworth Business Park South Whinby Road Dodworth Barnsley S75 3SP salus tech Salus PL07 Manual Ve...