UM-B-041
SmartBond Production Line Tool
User Manual
Revision 4.8
02-Nov-2022
CFR0012
134 of 170
© 2022 Renesas Electronics
#
Step
Description
19 Calculate the RF
path loss
To calibrate the RF result to -10 dBm we should apply the formula shown in the third
column below.
DUT
=AVERAGE(B1:K1)
Row L
Path Loss=-10-L1
DUT 1
-29.10
19.10
DUT 2
-27.41
17.41
DUT 3
-28.07
18.07
DUT 4
-29.11
19.11
DUT 5
-26.68
16.68
DUT 6
-23.05
13.05
DUT 7
-29.19
19.19
DUT 8
-39.64
29.64
DUT 9
-27.71
17.71
DUT 10
-37.18
27.18
DUT 11
-35.26
25.26
DUT 12
-27.06
17.06
DUT 13
-33.02
23.02
DUT 14
-24.20
14.20
DUT 15
-25.53
15.53
DUT 16
-30.20
20.20
20 Apply the
calculated path
losses to the
SmartBond_CFG_PL
T.exe
PLT
configuration
executable.
21 Verify
Repeat steps 10 to 13 with the 10 PCBAs. Check the GU RX RSSI results in the 10
CSV files. The results should be very close to -10 dBm.