UM-B-041
SmartBond Production Line Tool
User Manual
Revision 4.8
02-Nov-2022
CFR0012
41 of 170
© 2022 Renesas Electronics
Step
Action
Opt. Description
32
Sensor test
Yes
Perform the sensor tests only if these are enabled.
33
Custom test
Yes
Perform any active custom test.
34
Current measure peripheral
Yes
Perform any active current measurement test for
peripherals.
35
Current measure sleep
Yes
Perform the sleep current measurement.
36
Power cycle or reset DUTs
Yes
Power cycle with VBAT or Reset DUTs t enter boot
procedure.
37
Open COM port and download
uartboot_da1470x.bin
Yes
If any of the memory actions is active (e.g., QSPI burn,
QSPI erase, etc.) download the
uartboot_da1470x.bin
to the devices.
38
Get
uartboot_da1470x.bin
version.
Yes
After
uartboot_da1470x.bin
has been downloaded,
commands can be sent to it. A command to get the
uartboot_da1470x.bin
firmware version is sent to the
devices.
39
GPIO watchdog
Yes
If the GPIO watchdog option is enabled, the firmware
will begin a periodic GPIO toggling during the whole
memory programming procedure.
40
QSPI/OSPI memory initialization
Yes
If any QSPI or OSPI operation is enabled, initialize the
memory connected to the appropriate interface.
41
QSPI/OSPI erase
Yes
Erase the QSPI or OSPI, either the entire or part of it
depending on the configuration.
42
QSPI/OSPI image write
Yes
If enabled, write the QSPI or OSPI with the customer
image. If verify is enabled, the contents of the QSPI or
OSPI will be read back and compared to the original
image downloaded.
43
Custom memory data
Yes
Write custom memory data, taken from a barcode
scanner, entered manually or through a CVS file.
44
OTP binary write
Yes
Write the OTP binary with the customer application
area. If verify is enabled, the contents of the OTP
memory will be read back and compared to the original
image downloaded.
45
OTP CS write
Yes
If enabled, PLT will program the OTP configuration
script area.
46
Memory read
Yes
Up to 10 memory read tests can be performed with up
to 256 bytes in length.
47
Power cycle or reset DUTs
Yes
Power cycle with VBAT or Reset DUTs t enter boot
procedure.
48
Scan test
Yes
If enabled, the GU will scan for device Bluetooth
®
LE
advertisements. For the DUTs to be scanned a valid
firmware must be burned into the OTP or QSPI flash
that sends Bluetooth
®
LE advertisements after power
up. Additionally, the BD address should be burned into
the OTP or the QSPI by the PLT.
The PLT expects to find devices in the air with the BD
addresses programmed by the same tool, so it can
match the BD addresses returned by the GU.