UM-B-041
SmartBond Production Line Tool
User Manual
Revision 4.8
02-Nov-2022
CFR0012
95 of 170
© 2022 Renesas Electronics
Figure 80: GUI PLT Retry Failed DUTs Message
If the DUT fails again, after the retest has finished the GUI PLT will remain in the
FINISHED
screen
) with the
FINISHED
button shown in red.
If
Run scripts when testing is finished
is enabled, pressing the finished button will execute the
selected script/executable. As with
Run scripts before testing starts
, PLT will wait until it
finishes or times out, depending on the selections made in Section
. If the script/executable
has returned on time, PLT will check the return code. Zero value indicates a successful completion.
Any other value is considered an error. In the case of an error (either time out or error result), a pop-
up message will appear indicating the return code.
7.3.3
Debug Console
shows the debug settings for all PLT applications including the GUI PLT. If at least
one debug session is enabled with the output set to
Console,
the GUI PLT will open a new console
window showing the desired debug information.
Debug Console
. Depending on the type of the message, a
different color is used:
DEBUG
messages are light blue,
INFO
messages are white and
ERROR
messages are red.
Figure 81: Debug Console