Option
Description
Dirty
When enabled, the Bluetooth
®
LE tester packet generator can use a dirty table to
transmit.
CRC alternate
When enabled, the Bluetooth
®
LE tester will alternatingly send packets with CRC
correct and CRC incorrect.
RSSI limit
The RSSI limit for pass/fail criteria in the RF RX sensitivity test. If the average RSSI
of the device after it has received the transmitted packets is less than this value, the
test will be considered as failed.
Packet error limit
This configures the PER limit for pass/fail criteria. If the percentage of the correct
packets received is less than the value entered here, the test will fail.
Path Losses per DUT
Figure 55: Path Losses per DUT
describes the available options for the
Path losses per DUT.
Based on the relative position of each DUT during RF tests and since the RF tests are performed
over the air, values can be used to correct for any path losses. These values are added to the limits
of the TX Power and RF RX RSSI tests. Additional information can be found in
Table 40: Path Losses per DUT from RF Tests Options
Option
Description
DUT1-16
Set the path loss value for each DUT. These will be added as corrections to the limits
of the TX Power and RF RX RSSI tests
7.2.6.6
GPIO/LED Test
Figure 56: GPIO/LED Tests
GPIO/LED Tests
can have multiple instances with different settings. Tests can be added or removed
using the two buttons (e.g.,
and
in
) at the bottom right side of each panel.
Note:
When adding or removing a test, all settings are refreshed with the values written to the XML
file, meaning that any unsaved settings will be lost.