R8C/1A Group, R8C/1B Group
7. Voltage Detection Circuit
Rev.1.30
Dec 08, 2006
Page 50 of 315
REJ09B0252-0130
7.1
VCC Input Voltage
7.1.1
Monitoring Vdet1
Vdet1 cannot be monitored.
7.1.2
Monitoring Vdet2
Set the VCA27 bit in the VCA2 register to 1 (voltage detection 2 circuit enabled). After td(E-A) has elapsed
(refer to
19. Electrical Characteristics
), Vdet2 can be monitored by the VCA13 bit in the VCA1 register.
7.1.3
Digital Filter
A digital filter can be used for monitoring the VCC input voltage. When the VW1C1 bit in the VW1C register
is set to 0 (digital filter enabled) for the voltage monitor 1 circuit and the VW2C1 bit in the VW2C register is set
to 0 (digital filter enabled) for the voltage monitor 2 circuit, the digital filter circuit is enabled.
fRING-S divided by 1, 2, 4, or 8 may be selected as a sampling clock.
The level of VCC input voltage is sampled every sampling clock cycle, and when the sampled input level
matches two times, the internal reset signal changes to “L” or a voltage monitor 2 interrupt request is generated.