Figure 17.3
Registers ADCON2 and AD
A/D Control Register 2
(1)
Symbol
Address
After Reset
ADCON2
00D4h
00h
Bit Symbol
Bit Name
Function
RW
NOTE :
1.
0 : Without sample and hold
1 : With sample and hold
RW
When the ADCON2 register is rew ritten during A/D conversion, the conversion result is undefined.
SMP
A/D conversion method select bit
Nothing is assigned. If necessary, set to 0.
When read, the content is 0.
—
(b7-b4)
—
—
(b3-b1)
RW
Reserved bits
Set to 0.
b7 b6 b5 b4
0
b3 b2 b1 b0
0 0
A/D Register
Symbol
Address
After Reset
AD
00C1h-00C0h
Undefined
(b15)
b7
(b8)
b0
b0
b7
RO
Nothing is assigned. If necessary, set to 0.
When read, the content is 0.
—
2 high-order bits in A/D conversion result
When read, the content is undefined.
Function
RO
RW
When BITS bit in ADCON1 register is set to 1
(10-bit mode).
When BITS bit in ADCON1 register is set to 0
(8-bit mode).
8 low -order bits in A/D conversion result
A/D conversion result