R01UH0136EJ0210 Rev.2.10
Page 538 of 800
Jul 31, 2012
M16C/64A Group
25. Multi-master I
2
C-bus Interface
25.2.3
I2C0 Address Register i (S0Di) (i = 0 to 2)
SAD6 to SAD0 (Slave address) (b7-b1)
Bits SAD6 to SAD0 indicate a slave address to be compared for a slave address match detection in
slave mode. Up to three slave addresses can be set. Set the S0Di register to 00h when not setting the
slave address.
However, when the MSLAD bit in the S4D0 register is 0, registers S0D1 and S0D2 are disabled. Only
the slave address set to the S0D0 register is compared with address the data received.
b7 b6 b5 b4
b1
b2
b3
I2C0 Address Register i (i = 0 to 2)
Symbol
S0D0
S0D1
S0D2
Address
02B2h
02BAh
02BBh
Bit Symbol
Bit Name
RW
—
(b0)
Reset Value
0000 000Xb
0000 000Xb
0000 000Xb
b0
Function
SAD0
SAD1
SAD2
SAD6
RW
RW
RW
RW
SAD3
SAD4
RW
RW
SAD5
RW
No register bit. If necessary, set to 0. The read value is undefined.