R01UH0136EJ0210 Rev.2.10
Page 684 of 800
Jul 31, 2012
M16C/64A Group
30. Flash Memory
30.8.5.7
Read Lock Bit Status
The read lock bit status command is used to read the lock bit state of a specified block.
By writing xx71h in the first bus cycle and xxD0h to the highest even address of a block in the second
bus cycle, the FMR16 bit in the FMR1 register stores information on the lock bit status of a specified
block. Read the FMR16 bit after the FMR00 bit in the FMR0 register becomes 1 (ready). Do not
execute other commands while the FMR00 bit is 0.
Figure 30.13 shows a flowchart of the Read Lock Bit Status Command.
Figure 30.13 Read Lock Bit Status Command
Write command code xx71h
to X address
FMR00 = 1?
No
Yes
Write xxD0h to BA address
Start
Read lock bit status
completed
Read the FMR16 bit