42
J200: Tachometer Scaling Jumper
NOTE:
This jumper is on all controller models and is factory set for
7 VDC/1000 tachometer scaling (pins 1 and 2).
1. If 20.8 VDC/1000 tachometer scaling is desired, relocate jumper to
the 21V position (pins 3 and 4).
2. If the controller is to be used as a voltage regulator, or torque
regulator, leave this jumper set for the factory setting of 7 VDC/1000
(pins 1 and 2).
J5: Controller Output Current Jumper
NOTE:
This jumper is on all controller models and is factory set for
2.5 amperes.
1. Select the appropriate controller output current rating from the Table
41.
2. Position J5 for the current rating selected in Step 2.
Table 41. Controller DC Output Current Rating.
!
Controller Output
Current Rating by
Input Voltage Rating
115 VAC
230 VAC
Motor
HP
1/4
1/3
1/2
3/4
1
11/2
2
2.5
5.0
5.0
7.5
10.0
-
-
-
-
2.5
5.0
5.0
7.5
10.0
!
Measured with average reading DC ammeter.
J8: Process Control Interface Jumper
(On 05721031 Regulator Boards only)
NOTE:
This jumper is on process control interface controllers
(Models DC242, 44, 46, 52, 54, 56, 62, 64, 66, 72, 74, 82, 84, 92,
94 and 97) and is factory set for a 10V input signal.
1. Select the J8 jumper position based on the process control signal to
be used:
Process Control
Jumper
Input
Signal
Position
Impedance
1-5mA
5mA (Pins 5 and 6)
2K
W
4-20mA
20mA (Pins 3 and 4)
450
W
10-50mA
50mA (Pins 1 and 2)
200
W
0-10VDC
10 V (Pins 4 and 6)
666
W
Содержание DC2 VS series
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 5: ......
Страница 31: ...3 16 419 519 TB2 Motor Mounted D C Tachometer Figure 3 8 D C Tachometer Connection...
Страница 48: ...5 6 Figure 5 1 Wiring Diagram of Basic Speed Controller 0 57210 30...
Страница 49: ...5 7...
Страница 51: ...5 9 J4...
Страница 53: ...5 11 DEVICE INTERCONNECTIONS BACK OF REVERSING SWITCH Figure 5 3 Operator Device Interconnections...
Страница 56: ...Reliance Electric 24701 Euclid Avenue Cleveland Ohio 44117 216 266 7000 Printed in U S A D2 3231 3 March 1994...