41
4:
Setup and Adjust the Drive
DANGER
ONLY QUALIFIED ELECTRICAL PERSONNEL FAMILIAR WITH THE CON
STRUCTION AND OPERATION OF THIS EQUIPMENT AND THE HAZARDS IN
VOLVED SHOULD INSTALL, ADJUST AND/OR SERVICE THIS EQUIPMENT.
READ AND UNDERSTAND THIS MANUAL IN ITS ENTIRETY BEFORE PRO
CEEDING. FAILURE TO OBSERVE THIS PRECAUTION COULD RESULT IN SE
VERE BODILY INJURY OR LOSS OF LIFE.
DANGER
THIS EQUIPMENT IS AT LINE VOLTAGE WHEN AC POWER IS CONNECTED.
DISCONNECT AND LOCKOUT ALL UNGROUNDED CONDUCTORS OF THE
AC POWER LINE. FAILURE TO OBSERVE THESE PRECAUTIONS COULD
RESULT IN SEVERE BODILY INJURY OR LOSS OF LIFE.
Review all setup and adjustment instructions thoroughly before making
any adjustments or applying power to the controller. For your
convenience throughout the setup and adjustment procedures, use
Figure 41 or Figure 41A to locate adjustment pots, terminal boards,
special selector jumpers and pins. Wiring diagrams are given in
Figures 51, 51A, 52 and 53.
Position the Controller
Jumpers to Fit Application
The controller can operate on either 115V or 230V at multiple
horsepower ratings and in various modes. Make sure the circuit
jumpers are properly set for the application as described on the
following pages. See Figure 41, which locates these special selector
jumpers and pins.
J4: AC Input Voltage Jumper
NOTE:
This jumper is on all controller models and is factory set for
230 VAC.
1. Verify that J4 is positioned to match AC input line power.
2. If operation is on 115V, relocate J4 to the 115volt jumper position.
J3: Voltage/Tach Feedback Selection Jumper
NOTE:
This jumper is on all controller models and is factory set for a
voltage feedback of 180V.
1. If operation is to be on 115V with voltage feedback, relocate J3 to
the 90V jumper position.
2. If a tachometer feedback is to be is used, relocate J3 to `TACH'
position irrespective of input voltage.
Содержание DC2 VS series
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 5: ......
Страница 31: ...3 16 419 519 TB2 Motor Mounted D C Tachometer Figure 3 8 D C Tachometer Connection...
Страница 48: ...5 6 Figure 5 1 Wiring Diagram of Basic Speed Controller 0 57210 30...
Страница 49: ...5 7...
Страница 51: ...5 9 J4...
Страница 53: ...5 11 DEVICE INTERCONNECTIONS BACK OF REVERSING SWITCH Figure 5 3 Operator Device Interconnections...
Страница 56: ...Reliance Electric 24701 Euclid Avenue Cleveland Ohio 44117 216 266 7000 Printed in U S A D2 3231 3 March 1994...