MANUAL TEST FUNCTIONS
73
The first image below shows an FDR test for the
“Live”
position. The second image shows a
known good FDR test on a similar line in the
“Ref”
position.
Finally, we see the comparison of the two tests on the same screen which shows a fault on the
“Live”
line at approximately 96 feet.
Live
Live Data Selected
Comparison of “Live” and Known Good Reference
Reference Data Selected