Operation
Technical service - Rights reserved - Reproduction prohibited
When Eco-Stop puts the stove into stand-by mode this is
signaled by green and orange leds flashing alternately every
2''.
Eco-Stop switches the stove back on when both of the
following conditions are present:
At least 5' have elapsed since the switch off process
began.
Room T is at least 2°C below the set temperature (e.g. set
to 20°C, restarts when the temperature drops to 18°C).
If an external thermostat is used for operation, this is the
element that controls re-starting (e.g. in some thermostats
the delta can be set to between 0.5°C and 1.5°C).
N.B.: to exclude a momentary indication, the
aforementioned conditions must be present for 10''
consecutive.
When Eco-Stop switches the stove back on, this is indicated by
a green flashing led (as with normal start-up).
If the stove is switched off manually using the On/Off button
while Eco-Stop is active, the next time the stove is restarted
the function will still be active.
If there is a black-out while the stove is switched on or in
stand-by mode with Eco-Stop active, when the stove restarts
Eco-Stop will switch it off and then on again (if the
temperature is not satisfactory, with a delay of 120'').
Deactivation:
press the On/Off button briefly 5 times in a row within a
period of 6''. The card responds by sounding a long beep to confirm (4
seconds).
4.15.
Connection to programmable timed
thermostat (optional RED accessory)
The room timer is not included with the stove. The
user is responsible for fitting this part.
Refer to the instructions given in the optional programmable timed
thermostat for information on how to install it.