PELLET STOVES
Chapter 6
red
INSTALLATION AND USE MANUAL
page
41
Problems/Causes/Solutions
Technical service - Rights reserved - Reproduction prohibited
PROBLEM
LED
POSSIBLE CAUSES
Solutions:
The stove is
signalling pellet
hopper temperature
over the safety limit
Led 0.
Pellet load too high
Room fan power too low
The door is not closed properly or the seals
are worn.
Combustion chamber dirty
Outlet obstructed
Pressure switch faulty or broken
Structure has overheated due to
reduced heat dissipation.
Room fan faulty
Wait for the stove to cool,
re-ignite it and decrease the
pellet load following the
instructions in section 4.10
Wait for the stove to cool,
re-ignite it and increase the
fan using knob A
Close the door or have the
seals replaced with original
spares
Clean the combustion
chamber according to the
instructions in the manual
Clean the smoke duct
Replace the pressure switch
Verify the correct
positioning of the stove
Increase the smoke fan
speed according to the
technical manual
Replace the room fan
The stove signals
anomalous
operation of the
smoke fan
Led +1
Impediment in fan rotation
Smoke fan faulty
Check the reason for the
impediment
Replace the faulty
component
The stove signals
smoke temperature
too high or smoke
probe faulty
Led +2
Pellet load too high
Unsuitable pellets.
Room fan power too low
Structure has overheated due to
reduced heat dissipation.
Room fan faulty
Smoke probe faulty
Smoke outlet blocked
Increase the pellet load
following the instructions in
section 4.10
Remove the unsuitable
pellet from the hopper and
exchange it with one
recommended by the
manufacturer
Increase the fan speed
using knob A
Verify the correct
positioning of the stove
Replace the faulty
component
Clean the smoke outlet
The stove signals
that the door is
open
LED -2
LED -1
The door was not shut properly
Make sure it is shut
The stove signals
the pressure switch
LED -1
LED 0
Draught problem
Clogged brazier
Check or if necessary clean
the brazier and flue pipe of
any incrustations
Check whether the brazier is
in place
Pellet hopper door
open
LED 0
LED +1
The door is not shut properly due to an
excess pellet load in the hopper
A few pellets are not in place
Reduce the pellet level in
the hopper.
Check whether anything is
preventing the door from
being shut properly
Содержание Dalia Oyster