Operation
Technical service - Rights reserved - Reproduction prohibited
4.12.
Connection to a room thermostat
The room thermostat is not included with the stove
and it must be installed by a specialised technician.
WARNING!
The electrical wires must not be in contact with the
hot parts of the stove.
The stove can also be connected to a room thermostat. The procedure
to follow for the connection of the external thermostat is the following:
Connect the two wires of the cable which come from the room
temperature to the two free terminals of the connector
(
position
13
wiring diagram chap.7). To do this it is
necessary to:
o
unscrew the protective cap of the probe
o
Pass the two wires through the protective cap and
insert them into the hole together with the probe.
o
Pull the two wires to carry out connection to the board
corresponding to terminal 13 (see chap.7)
o
Close the protective cap again.
4.13.
Accessing the motherboard
Perform the following operations working behind the stove:
remove the four screws
X
remove the cover
U
remove the two screws
Y
remove the cover
U
remove the motherboard
S
Make the connections to the card and replace the covers