ANALOG TYPE
Enter the analog output type. For voltage output use terminals 16 and 17. For
current output use terminals 18 and 19. Only one range can be used at a time.
Select the display that the analog output is to follow:
Enter the display value within the selected Analog Assignment that
corresponds to the high limit of the type selected.
The decimal point is determined by the decimal point setting of the assigned
counter or rate. The scale value can not be set to read values with more than 6
digits. Reverse acting output is possible by reversing the scaling values.
-99999
to
999999
-99999
to
999999
Module 8 is the programming for the analog output parameters. To have an
analog output signal, an analog output plug-in card needs to be installed (See
Ordering Information). This section replaces the bulletin that comes with the
analog plug-in card. Please discard the separate literature when using the plug-
in card with the PAXI.
SELECTION
RANGE
0-20
0 to 20 mA
4-20
4 to 20 mA
0-10
0 to 10 V
HI
C CNt
LO
b CNt
rAtE
A CNt
Enter the display value within the selected Analog Assignment that
corresponds to the low limit of the type selected.
The decimal point is determined by the decimal point setting of the assigned
counter or rate. The scale value can not be set to read values with more than 6
digits. Reverse acting output is possible by reversing the scaling values.
RESTORE FACTORY DEFAULTS
Use the arrow keys to display
/+$1 AA
and press
PAR
.
The meter will display
!1%1'
and then returns to
/+$1 72
.
Press
DSP
key to return to the Display Mode. This will
overwrite all user settings with the factory settings.
Pressing the
PAR
and
DSP
keys at the same time on power-up will load the
factory settings and display
1!!@
. This allows operation in the event of a
memory failure or corrupted data. Immediately press
RST
key and reprogram
the meter. If the meter is powered down again before pressing the
RST
key, the
existing dynamic data will not be overwritten.
!
"
AA
/+$1
6.8 MODULE 8 - A
NALOG
O
UTPUT
P
ARAMETERS
(
<0:9:
)
6.9 MODULE 9 - F
ACTORY
S
ERVICE
O
PERATIONS
(
=0-!$
)
Enter the desired Display Intensity Level (0-15) by
using the arrow keys. The display will actively dim or
brighten as the levels are changed. This parameter also
appears in Quick Programming Mode when enabled.
DISPLAY INTENSITY LEVEL
!
"
?
$8#1:
PAXI O
NLY
= Counter C Value
= Maximum Value
C CNt
HI
= Counter B Value
= Minimum Value
b CNt
LO
= Counter A Value
= Rate Value
A CNt
rAtE
Содержание CUB 1
Страница 30: ...7 This page intentionally left blank...
Страница 46: ...5...
Страница 47: ...6...
Страница 48: ...7...