DIMENSIONS & INSTALLATION FOR CUB 1 & CUB 2, “XP” VERSIONS
Counters should be mounted in a panel grounded to the machine frame. After
cutting opening in panel, slide the panel gasket over the rear of the counter body
to the back of the bezel. Then slide counter through the panel cut-out. Install
mounting clips on each side of the counter body with mounting screws. Make
sure the side rails or tabs of the clips fit into the recesses in the side of the
counter body so that the
“Tang Ends”
or
“Tabs”
wedge between the panel
opening and body as the screws are tightened.
BATTERY COVER REMOVAL & BATTERY INSERTION
CUB1XP
The battery cover is held in place by upper and lower clasps that capture
mating lock ramps on the cover. To remove, insert thumbnail and index finger
nail in the gaps between the upper and lower clasps and the battery cover, and
deflect the clasps slightly to clear the edges of the ramps while pulling out on
the cover. To replace cover, simply push into place until both clasps snap into
engagement with lock ramps.
CAUTION: Do not deflect clasps more than necessary to clear lock ramps.
Excessive deflection can cause clasps to break off.
CUB2XP
Slide battery cover to the left until the right hand lip disengages and pops out.
To reinstall cover, insert left hand lips into case first, push cover to the left until
right hand lip drops down and cover snaps back into place. Install batteries as
shown below observing proper polarity.
Note: Push battery spring clips to the left (toward connector) to completely free
the batteries when removing or installing batteries. Conductive rubber
battery contacts can be torn from their retaining pins if batteries are forced
in.
REMOVING & INSERTING CONNECTOR LEADS
Connector and lead assemblies are shipped with counters with leads installed
as shown. Connector body is held in place by the battery cover which must be
removed to disengage connector.
Removing Terminal:
Insert blade of a small screwdriver into slot of connector
body, and gently push in to disengage the lock pawl. Pull terminal out.
Inserting Terminal:
When inserting into connector body, make sure the lock
pawl is toward the slot in the body. Push terminal in until the lock pawl snaps
into slot.
REMOVING & INSERTING CONNECTOR LEADS
Wiring runs to count-switches or to remote reset contacts can be made with
almost any kind of wire and over distances of hundreds of feet, due to the
advantages of low-voltage low-current operation. The inherent noise immunity
and heavy filtering built into CUB Counters, permits use of unshielded wiring,
however the following precautions are advisable especially in high electrical-
noise environments.
1. Avoid long wire runs in cable troughs or conduits with power circuits.
2. Mount the CUB in a panel that is grounded to the machine frame.
WARNING:
INSTALL ONLY APPROVED BATTERIES. USING OTHER
BATTERIES WILL VOID APPROVAL FOR USE IN HAZARDOUS
LOCATIONS. (See Specifications)
.
CUB1XP
CUB2XP
DIMENSIONS “In inches (mm)”