SPECIFICATIONS
1.
DISPLAY:
6-digit, 0.3” (7.6 mm) high LCD display.
2.
POWER REQUIREMENTS:
25 mA @ 5 VDC (±5%) or
25 mA @ 10 to 30 VDC.
Must use a Class 2 or SELV rated power supply.
3.
COUNT INPUT:
Accepts count pulses from a variety of sources, including
switch contacts and outputs from CMOS or TTL circuits.
Current Sinking
: Unit provides 10 K
Ω
pull-up for sensors with current
sinking outputs. (I
SNK
= 0.5 mA; max. input voltage, 28 VDC @ 8 mA.)
Debounce
: Switch selectable damping capacitor provided for switch contact
debounce. Limits count speed to 50 Hz max. with 50% duty cycle.
Input Trigger levels
: V
IL
= 2.3 V, V
IH
= 3.1 V.
4.
PRESCALE VALUE RANGE:
0.00001 to 9.99999.
5.
MAXIMUM COUNT RATES:
High Frequency
: The following chart lists the count rates for all the possible
prescale values.
(maximum square wave input for all electronic sensors,
under all modes of operation.)
Prescale Value
Frequency
0.00001 to 1
11.0 KHz
1.00001 to 2
8.0 KHz
2.00001 to 3
6.5 KHz
3.00001 to 4
5.0 KHz
4.00001 to 5
4.5 KHz
5.00001 to 6
4 KHz
6.00001 to 7
3.5 KHz
7.00001 to 8
3 KHz
8.00001 to 9
2.5 KHz
9.00001 to 9.99999
2.0 KHz
Note: For prescale values greater than 7, the timed delay output is affected
by the count speed (rate).
Low Frequency
: 50 Hz max. for switch contact closures. Note: These units
will operate with VCM (E through H) modules.
6.
CONTROL INPUTS:
Active low (V
IL
= 0.5 V max.), internally pulled up
to 5 VDC through a 10 K
Ω
resistor (I
SNK
= 0.5 mA).
Remote Reset
: Response time = 10 msec. A low will reset the unit and
deactivate outputs.
Program Disable
: A low will inhibit the changing of presets, prescale, and
timed outputs, as well as testing outputs in self-test.
Up/Down Contro
l: Response time = 150 µsec. A low will cause the unit to
count down. A high will cause the unit to count up.
7.
OUTPUTS:
Solid-State
: Current sinking NPN Open Collector Transistors.
I
SNK
= 100 mA max., V
OH
= 30 VDC max., V
OL
= 1 V @ 100 mA.
One solid-state output for each preset level.
Programmable Timed Output
: The timed output can be programmed from
0.01 sec. to 99.99 sec., ±0.1% + 10 msec. The timed output is set for 0.1
sec. at the factory.
8.
MEMORY RETENTION:
Non-volatile E
2
PROM retains all programmed
information when power is removed or interrupted.
Power Cycles(ON/OFF)
: 100,000 min.
Data Retention
: 10 years min.
9.
INPUT, POWER, AND OUTPUT CONNECTIONS
: Fixed terminal
block.
10.
CERTIFICATIONS AND COMPLIANCES
:
EMC EMISSIONS
:
Meets EN 50081-2: Industrial Environment.
CISPR 11 Radiated and conducted emissions
EMC IMMUNITY
:
Meets EN 50082-2: Industrial Environment.
ENV 50140 - Radio-frequency radiated electromagnetic field
ENV 50141 - Radio-frequency conducted electromagnetic field
1
EN 61000-4-2 - Electrostatic discharge (ESD)
EN 61000-4-4 - Electrical fast transient/burst (EFT)
1
Notes:
1. Power Lines - Power lines had an external EMI filter, Schaffner FN610-1
(RLC #LFIL0000) or equivalent, installed.
Refer to the EMC Installation Guidelines section of this bulletin for
additional information.
11.
ENVIRONMENTAL CONDITIONS
:
Operating Temperature
: 0 to 50°C
Storage Temperature
: -40 to 70°C
Operating and Storage Humidity
: 85% max. relative humidity (non-
condensing) from 0°C to 50°C.
Altitude
: Up to 2000 meters
12.
CONSTRUCTION
: Black plastic front bezel with black plastic insert.
Front panel meets NEMA 4X/IP65 requirements for indoor use when
properly installed. (Panel gasket, mounting clip, nut fasteners, and screws
included with unit.) Installation Category I, Pollution Degree 2.
13.
WEIGHT:
0.2 lbs (91 g).
INPUT CONFIGURATION, FRONT PANEL
RESET, & DIP SWITCH SET-UP
The DIP switches are located at the rear of the unit. DIP switch 1 is used to
select high or low frequency. DIP switch 2 is used to enable or disable the front
panel reset button. DIP switch 7 is used to enable or disable prescale changes.
DIP switches 3 to 6 are used to select the mode of operation. Refer to the block
diagram of the unit for the details of count and control circuitry.
SWITCH SET-UP
S1 - HI FRQ.:
Removes damping capacitor and allows operation up to the
maximum frequency (See max count rates in specifications).
LO FRQ.:
Connects damping capacitor for switch contact de-bounce.
Limits count speed to 50 Hz. Minimum count ON/OFF times - 10
msec.
S2 - DIS.RST.:
Disables front panel reset.
EN. RST.:
Enables front panel reset.
S3 to S6:
These are the mode select DIP switches. See Modes of Operation
for the switch settings of a specific mode.
S7 - PRESCALE EN./DIS.:
When S7 is in the DOWN position, prescale
information can be changed. When S7 is in the UP position,
prescale information cannot be changed.
BLOCK DIAGRAM